Using adorne Wireless Lighting Dimmers, Switches, and

Plug-In Modules

Dimmers

Common Device Applications

Security Systems
Connect adorne Scene Interfaces and security systems using a two-wire connection between a maintained
or momentary output relay at the alarm panel and the desired input on the scene interface. Common
applications include switching on or flashing house lighting when an alarm event occurs or recalling a
scene when the homeowner deactivates the alarm system upon arrival.

Occupancy or Vacancy Sensor
An occupancy sensor application could use either Mode A or Mode B. Most applications would use Mode B.
In this configuration, a scene executes when the sensor initially detects motion; a second scene executes
when the sensor determines that the space is unoccupied. Mode A allows auto-on, manual-off, and
manual-on/auto-off functions. A manual-on/auto-off application requires the input to be wired to a NC
contact and the scene stored to turn the appropriate lighting off.

OPERATING THE SYSTEM

EXPANDING THE SYSTEM AND INTERFACING WITH OTHER PROGRAMS

Security

Panel

Room or House

Scene Interface

24VDC Out.

(150ma max.)

Ground

Input 1

Input 2

Input 3

Power

Ground

COM

NO

2/20AWG

Motion

Sensor

Setting

Default

Button Operation

On/Off

Tap once

Fade the circuit to its last-used level

On/Off

Tap twice

Full bright

On/Off

Press and hold

Fade the circuit to off

+ or upper-right

Tap once

From Off, fade the circuit to its last-used level

+ or upper-right

Tap once

From On, increase level 2% per tap

+ or upper-right

Tap twice

From Off, full bright

+ or upper-right

Tap twice

From On, increase level 4%

+ or upper-right

Press and hold

Continually increase the light level

- or lower-right

Tap once

Decrease level by 2% per tap

- or lower-right

Tap twice

Decrease level by 4%

- or lower-right

Press and hold

Continually decrease the light level

Setting

Default

Button Operation

On/Off

Tap once

From Off, turn circuit on

On/Off

Tap once

From On, turn circuit off

Switches

Setting

Default

Button Operation

Tap once

Fade the circuit to its last-used level

Tap twice

Full bright

Press and hold

Continually increase the light level

Tap once

Fades the circuit to off

Press and hold

Continually decrease the light level

Plug-in Lamp Modules

Setting

Default

Button Operation

Tap once

Turn circuit on

Press and hold

Turn circuit on

Tap once

Turn circuit off

Press and hold

Turn circuit off

Plug-in Appliance Modules