Tbar operation, Normal – JLCooper ES-SloMoJ User Manual
Page 31
31
TBar Operation
The TBar may be set via "TBar Range" to Normal, 5%, 10%, or
bidirectional operation.
Normal
There are three main aspects of the "Normal" speed operation of
the TBar, as follows:
Full Range Operation
Press the ENABLE button. As soon as the TBar is moved, a
speed command (depending on message choice made in the
Menu) will be sent. The range of operation is from Still (all the
way toward the operator) to 10x normal play speed.
A subsequent press of the ENABLE button will turn the TBar
off. Depending on selection within the Menu, the pressing of
any "transport" button (REW, R-PLAY, STOP, PLAY, FFWD)
may be made to turn the TBar off.
Scaled Range Operation
Press the T1 button. The TBar will be enabled. The Minimum
speed of the T Bar will now be the value set in the Menu Item
TBar
Speed
Min
. The Maximum speed will now be the value set
in the Menu Item
TBar
Speed
Max
.
Preset Operation
It might be desired to be able to always start T Bar operation at
a know speed different from the Max or Min value. When the
PRESET button is pushed, a speed value equal to the speed set
in the Menu Item "TBar Speed Preset" will be immediately
sent. That speed will be shown on the second line of the
display. Unless the TBar happens to be sitting at the Preset
speed, the PRESET LED will blink indicating that the T Bar
needs to be moved to the "null" point (the point where the T
Bar position is the same as the Preset).
On the far right of the display, an up or down arrow will show