Installing TopKAT Series 900 Replacement Report Printer Kit

Page 8

MDE-5061 TopKAT™ Series 900 Replacement Report Printer Kit (M11810K001) Installation Instructions · March 2013

14

Turn on the power and check for 24 V between Ground (GND) and Printer Voltage (VP) on
the new Printer Controller PCA [M11960A001 (see

Figure 5

)]. Adjust the supply to 24 V by

turning the potentiometer located on the upper left corner of the printer power supply. Turn
clockwise to increase the voltage and counter-clockwise to decrease the voltage.

Figure 5: Installing New Printer Controller PCA

GND Test Point

VP Test Point

15

Reinstall the power supply cover and secure it with the three screws removed in step

7

on

page 5

.

16

To load the paper, push Paper Pressure Level towards the front of the TopKAT unit (see

Figure 6

), feed the paper about 3 inches into the paper slot, and then pull the Paper Pressure

Level back to the closed position.

Figure 6: Loading the Paper

Paper Slot

Paper Roll

Paper Path

(ii)

(i)

Paper Pressure Level