Introduction
This manual provides instructions to install the Submersible Drive Relay Kit (M05816K00X)
for the direct drive of submersible pumps, up to 3/4hp, 120v and up to 1-1/2hp, 240v (not
required with external relay box).
Intended Users
This manual is intended for Gasboy Authorized Service Contractors (ASCs).
Single and Dual Relay Kits
Kit No.
Description
M05816K001
Single Submersible Drive Relay Kit
M05816K002
Dual Submersible Drive Relay Kit
Required Reading
Before installing a kit, the installer must read, understand, and follow:
• This manual
• NFPA 30A, The Automotive and Marine Service Station Code
• NFPA 70, The National Electric Code
• Applicable federal, state and local codes and regulations
Failure to do so may adversely affect the safe use and operation of the equipment.
Note: This kit must be installed by a Gasboy ASC to ensure warranty.
Required Tools
• # 2 Phillips
®
screwdriver
• # 1 Phillips screwdriver
MDE-4596
Atlas
™
Submersible Drive Relay Kits
(M05816K00X)
Installation Instructions
August 2006
Document Outline
- Introduction
- Important Safety Information
- Installing the Atlas Submersible Drive Relay Kit
- Preparing for the Installation
- Installing the Atlas Submersible Drive Relay Kits
- 1 Unlock and remove the front panel.
- 2 Remove the two screws securing the bezel assembly and remove the assembly.
- 3 Remove the two screws securing the display panel and pivot display panel down. The unit will swing forward and down after screws are removed.
- 4 Pull the connector off P1 on the power supply. After a few seconds, reconnect P1.
- 5 Attach the relay module to the platform base using M4 screws.
- 6 Attach the relay cable to P7 of the display CPU board.
- 7 Locate the 14 gauge red and blue wires coming from the AC conduit under the platform (marked K1-1 and K1-2 respectively). Dual dispensers will also use the 14-gauge orange and black wires (marked K2-1 and K2-2 respectively).
- 8 Attach the red wire to screw terminal #1 and the blue wire to screw terminal #2 of relay #1. Attach the orange wire to screw terminal #1 and the black wire to screw terminal #2 of relay #2.
- 9 Complete the wiring between the breaker panel, pump and AC J-Box as shown in FE357B Atlas Pump Retail/Commercial Field Wiring Diagram.
- Completing the Installation
- 1 Reassemble the pump (fasten the display panel in place, install and secure the bezel assembly, and install and lock the front panel).
- 2 Inform the manager/owner that the circuit breakers for MICRO, LIGHTS and FEED will be turned on and then turn them on.
- 3 Remove the lockout/tagout and return to normal operation.