Installing the Atlas Submersible Drive Relay Kit

Page 6

MDE-4596 Atlas™ Submersible Drive Relay Kits (M05816K00X) Installation Instructions · August 2006

4

Pull the connector off P1 on the power supply. After a few seconds, reconnect P1.

P1

5

Attach the relay module to the platform base using M4 screws.

CPU

Power
supply

Pulser

Single

Dual

Main
Conduit

Micro
power

Lights

Heater

Pulser

K1-1

K1-2

K2-1

K2-2

L bracket

Relay
1

Relay
2

Note: Single dispensers will use only relay 1, whereas twins will use both relays (1 and 2).

6

Attach the relay cable to P7 of the display CPU board.

7

Locate the 14 gauge red and blue wires coming from the AC conduit under the platform
(marked K1-1 and K1-2 respectively). Dual dispensers will also use the 14-gauge orange and
black wires (marked K2-1 and K2-2 respectively).

8

Attach the red wire to screw terminal #1 and the blue wire to screw terminal #2 of relay #1.
Attach the orange wire to screw terminal #1 and the black wire to screw terminal #2 of relay
#2.

9

Complete the wiring between the breaker panel, pump and AC J-Box as shown in FE357B
Atlas Pump Retail/Commercial Field Wiring Diagram.