MDE-4447A Global Pumping Unit Operation and Service Manual · May 2008

Page 9

Pumping Units with Throw-Out Rings

Pumping Unit Operation and Maintenance

Pumping Units with Throw-Out Rings

All pumping units have rotors with throw-out rings and carbon blades.

Note: Studies conclude that pumping units with throw-out rings produce greater vacuum and

are more resistant to vapor lock.

To replace blades in rotors with throw-out rings, proceed as follows:

1

Install throw-out rings in the recesses of the rotor.

2

Install the rotor in the stator assembly.

3

Rotate the rotor until a blade slot is at the 12:00 o'clock position. Install a blade.

4

Rotate the rotor two slots from the installed blade. Ensure that the second slot is at the 12:00
o'clock position. Install a blade.

5

Repeat step

4

for the third blade.

6

Repeat steps

1

to

3

for the three remaining blades. See

Figure 3-7

.

Figure 3-7: Pumping Units with Throw-Out Rings

Blade Slot at 12:00 o’clock Position

Stator

Throw-out Rings

Rotor and Shaft
Assembly