Pumping Unit Operation and Maintenance
Lip Seal Replacement
Page 8 MDE-4447A Global Pumping Unit Operation and Service Manual · May 2008
Lip Seal Replacement
To replace the lip seal, proceed as follows:
1
Remove the belt, pulley, and shaft key.
2
Remove the three screws that hold the seal retainer. See
. Carefully pry the old seal
from the recess in the cover plate.
Note: Do not scratch the shaft.
3
Wipe the shaft clean.
4
With a small plastic plug tool (furnished with new seal), slip the new seal over the shaft.
Remove the tool.
5
Reinstall the seal retainer screws, key, pulley, and belt.
Figure 3-6: Lip Seal Replacement
Stator
Lip
Seal
Seal
Retainer
Inner
Seal
Screw
Remove Plastic Plug
After Assembling Lip
Seal to Rotor Shaft
A 52 5702
See also other documents in the category Gasboy Hardware:
- 216S (18 pages)
- Atlas Fuel Systems Site Prep Manual (42 pages)
- Atlas Technician Programming Quick Ref (2 pages)
- ATC M05819K00X Kits (28 pages)
- Atlas Fuel Systems Owner Manual (80 pages)
- 26 (7 pages)
- Atlas Valve Replacement Kits (10 pages)
- Atlas Fuel Systems Installation Manual (100 pages)
- 9120K (8 pages)
- 9820K (6 pages)
- Atlas Single Std. Inlet Centering Kit (8 pages)
- 8800 Atlas (1 page)
- 9120K Series Service Manual (40 pages)
- 9800A Atlas (6 pages)
- 9800 Atlas (14 pages)
- 9800 Atlas (20 pages)
- M08400 (6 pages)
- 9100 Series (8 pages)
- 9820K Series Installation (62 pages)
- 9853K (8 pages)
- 9216KTW (36 pages)
- Recommended Spare Atlas (14 pages)
- DEF Atlas (28 pages)
- 9820K Series (12 pages)
- 9800Q (1 page)
- Q Series (3 pages)
- 8753E (2 pages)
- 9152AXTW2 (1 page)
- 8800E (2 pages)
- 8800E (1 page)
- 9820Q Series (1 page)
- Atlas Start-up (230 pages)
- 2600A (12 pages)
- 2600A (2 pages)
- 9800Q Front Load Vapor (2 pages)
- 215A (1 page)
- 9800A (4 pages)
- 9820A (1 page)
- 2600A (3 pages)
- 215A (2 pages)
- 9800Q Vapor (2 pages)
- 216A (31 pages)
- Lamp Kit (2 pages)
- 9120Q Pulser (1 page)