Electrical

Supply Voltage

Input voltage (switch selectable)..............................................................................120 volts ac, 50/60 Hz

240 volts ac, 50/60 Hz

Power consumption ...................................................................................................... 33 watts (nominal)

82 watts (maximum)

48 volt tolerance............................................................................................................... 48 volts dc

±5%

48 volt current ....................................................................................................... 250 mA (idle, nominal)

1000 mA (maximum)

T1 Parameters

N

OTE

: The LE200 is not compatible with the public switched telephone network.

Encoding..................................................................................... (Bipolar with 8 Zero Substitution) B8ZS

Framing..........................................................................................................(Extended Superframe) ESF

E1 Parameters

N

OTE

: The LE200 is not compatible with the public switched telephone network.

Encoding..................................................................................................(High Density Bipolar 3) HDB3

Framing............................................................................................ (Cyclic Redundancy Check 4) CRC4

Signaling.............................................................................................(Common Channel Signaling) CCS

Copper Cabling

Type.............................................................Twisted pair data cable (i.e., CAT5), shielding recommended

Cable characteristic impedance, T1/E1 ..................................................................100

Ω/120 Ω (nominal)

Maximum cable length ............................................................................ 6,000 feet/1.8km (No. 22 AWG)

Maximum attenuation....................................................................................................................... 24 dB

Fiber Cabling

Refer to the bundled fiber transceiver’s manual.

LVDS Cabling

Type........................................................................................Straight-through Shielded CAT 5e Ethernet

Cable characteristic impedance........................................................................................ 100

Ω (nominal)

Maximum cable length ............................................................................................................... 10 meters

Line Balance Characteristics

Coupling .................................................................................................................................AC coupled

Adjustment range .................................................................... Disabled, 15 to 115

Ω adjustable (nominal)

Page Line or Party Line Maximum Peak Working Voltage

L1 to L2 ....................................................................................................................

±30 volts dc nominal

L1 or L2 to ground ..................................................................................................

±120 volts dc nominal