Pub. 42004-701L2F

M

ODEL

LE200

S

ERIES

W

ALL

-M

OUNT

P

AGE

/P

ARTY

®

L

INE

E

XTENDERS

P

AGE

34 of 50

f:\standard ioms - current release\42004 instr. manuals\42004-701l2f.doc
04/09

Rules for Interconnecting more than Two Model LE200s

When connecting more than two Model LE200s together, these rules must be followed.

• A maximum of two Model LE200 pairs can be connected in series when the series connections are

made using Page/Party

®

cable as shown below.

Figure 13. Maximum Series Connections

When Model LE200s are connected in series, a problem can arise when training echo cancellation. If
more than one Model LE200 is training echo cancellation on a signal line at the same time, then none
of them will train echo cancellation properly. To prevent this, power each line extender one at a time.
Wait for the echo cancellation to complete on the first line extender before powering the second.

• A maximum of eight pairs of Model LE200s can be connected in parallel. Parallel connections must

be made using the LVDS link and the T1/E1 link as shown below.

Figure 14. Maximum Parallel Connections