beautypg.com

Changed features compared to le100, New features compared to le100 – GAI-Tronics LE200, LE200-FSR, LE200-FLR Page/Party Line Extenders User Manual

Page 43

background image

Pub. 42004-701L2F

M

ODEL

LE200

S

ERIES

W

ALL

-M

OUNT

P

AGE

/P

ARTY

®

L

INE

E

XTENDERS

P

AGE

41 of 50

f:\standard ioms - current release\42004 instr. manuals\42004-701l2f.doc
04/09

Changing to a LE200 from a LE100

Changed Features Compared to LE100

An echo cancellation routine is added.

The LE200’s off-hook detector must be the only off-hook detector installed on a particular party line.
The LE200 supports only unidirectional off-hook propagation, while the LE100 supported bi-directional
off-hook propagation.

For copper T1/E1 connections, CAT 5 cable is specified instead of CAT 3 cable.
N

OTE

: The LE200 should work with CAT 3 cable; use CAT 5 cable, or better, for all new installations.

• The LE200 provides true relay outputs instead of polarized solid-state relay outputs.
• The LE200 is not able to connect to the LE100. The LE200 pairs must replace the LE100 in pairs.
• There exists an additional consideration related to echo cancellation when connecting Model LE200s

in series.

New Features Compared to LE100

• The LE200 has a LVDS interface expected to be used to avoid paralleling multiple LE200s on the

same Page/Party

®

cable.

• Page line ground faults can be propagated from the remote connection.
• The LE200 can report remote page line ground faults.
• The LE200 has an array of LEDs that can sometimes aid in troubleshooting.
• The LE200 has isolation relays that disconnect it from its (audio line) field wiring when it is not

powered.

• The LE200 has the ability to select either T1 or E1 signal specifications

This manual is related to the following products: