GAI-Tronics LE200, LE200-FSR, LE200-FLR Page/Party Line Extenders User Manual
Page 16

Pub. 42004-701L2F
M
ODEL
LE200
S
ERIES
W
ALL
-M
OUNT
P
AGE
/P
ARTY
®
L
INE
E
XTENDERS
P
AGE
14 of 50
f:\standard ioms - current release\42004 instr. manuals\42004-701l2f.doc
04/09
Table 8. Transmission Direction Hold Time on 69443-xxx PCBA
SW2-5 SW2-6 Transmission
Direction
Hold
Time
Open (up)*
Open (up)*
1280 milliseconds
Closed (down)
Open (up)
640 milliseconds
Open (up)
Closed (down)
160 milliseconds
Closed (down)
Closed (down)
40 milliseconds
N
OTE
: Changes to this parameter take effect without cycling power.
Table 9. Peak Voltage Level Detection Threshold on 69443-xxx PCBA
SW2-7
Peak Voltage Level Detection Threshold
Open (up)*
-12 dB relative to nominal
Closed (down)
-24 dB relative to nominal
N
OTE
: Changes to this parameter take effect without cycling power.
Table 10. Echo Cancellation Power-On Delay Setting on 69443-xxx PCBA
SW6-1
Echo Cancellation Power-On Delay
Open* One
minute
Closed No
delay
N
OTES
: 1. Changes to this parameter take effect when cycling power.
2.
*Indicates
default
position.