beautypg.com

Formax FD 150 User Manual

Page 19

background image

Operating Manual

1/97

15

4. Determine the proper fuse value as well as the

condition of the LINE FUSE. The fuse value is shown
on the metal tip of the LINE FUSE. The chart below
lists the selected voltage in the left column followed by
the proper fuse value in the right column.

Selected Voltage

Line Fuse Value

100V

1.0A (250V time delay)

120V

1.0A (250V time delay)

220V

0.5A (250V time delay)

240V (or 230V)

0.5A (250V time delay)


5. Replace the LINE FUSE if necessary. Both LINE

FUSES must be in place for the FD 150 to operate
properly.

6. Install the FUSE DRAWER in the POWER ENTRY

CASING.

4.4 Power Cord


The FD 150 comes with a three-wire POWER CORD. The
POWER CORD grounds the FD 150 when connected to an
approved three-contact electrical outlet.

1. Plug the POWER CORD into the APPLIANCE INLET

on the non-operator side. (Refer to Figure 4.1.)

2. Plug the POWER CORD into a grounded outlet.

WARNING

TO PREVENT ELECTRICAL SHOCK, ONLY PLUG
THE POWER CORD INTO A GROUNDED OUTLET.