beautypg.com

Formax FD 150 User Manual

Page 18

background image

Operating Manual

14

1/97


Figure 4.1 --

FD 150 Power Connection

4.3 Line Fuses


The FUSE DRAWER, located on the input end, contains
two LINE FUSES. (Refer to Figure 4.1.) The neutral and
hot lines of power are fused. Both LINE FUSES must be in
place for the FD 150 to operate properly.

CAUTION

VERIFY THAT THE LINE FUSE VALUE IS
CORRECT FOR THE VOLTAGE SETTING.
UNPLUG THE

FD 150 BEFORE STARTING THIS

PROCEDURE.

Use the following instructions to verify that the installed
LINE FUSES have the proper fuse value:
1. Unplug the POWER CORD.
2. Use a small screwdriver or similar tool to push up on

and release the FUSE DRAWER LOCKING TAB.

3. Pull the FUSE DRAWER out of the POWER ENTRY

CASING. The attached LINE FUSES are inside.