Trouble
Cause
Solution
1. Nothing works.
Power switch is not on.
Turn power switch on.
Power cord is
damaged or not
plugged into proper
outlet.
Replace power cord if
damaged or plug into
proper outlet if
necessary.
Outlet does not have
power present.
Check circuit source
for a blown fuse or
circuit breaker.
2. CLEAR TAB light
flashes 8-10
seconds after
CLEAR TAB is
turned on.
Sensor is blocked.
Remove all tabs and
debris from peel point
area. Tune sensor.
Refer to Section
9.1.2.
3. No tabs on mail
pieces.
TAB READY light is
off. Peel point is free
of tabs and debris.
Toggle ON/OFF until
light illuminates.
4. FD 260 shuts
down. TAB
READY light
starts flashing.
Sensor could not find
tab during the pre-set
time.
Tune sensor. Refer to
Section 9.1.2.
5. Not tabbing --
TAB READY light
remains on,
multiple tabs
peeled.
Incorrect CLEAR TAB
selection.
Make CLEAR TAB
selection for tabs
being run. Refer to
Section 9.1.2.
6. Not tabbing --
TAB READY light
is on but no tabs
at peel point.
Sensor is blocked by
debris.
Remove debris from
the peel point area
through the inspection
window.