beautypg.com

Troubleshooting – Formax FD 260 User Manual

Page 33

background image

29

8. TROUBLESHOOTING

WARNING

UNPLUG THE POWER CORD BEFORE

REMOVING, ADJUSTING OR REPAIRING ANY

PARTS IN THE

FD 260.

8.1
Troubleshooting
Chart

Trouble

Cause

Solution

1. Nothing works.

Power switch is not on.

Turn power switch on.

Power cord is

damaged or not
plugged into proper
outlet.

Replace power cord if

damaged or plug into
proper outlet if
necessary.

Outlet does not have

power present.

Check circuit source

for a blown fuse or
circuit breaker.

2. CLEAR TAB light

flashes 8-10
seconds after
CLEAR TAB is
turned on.

Sensor is blocked.

Remove all tabs and

debris from peel point
area. Tune sensor.
Refer to Section
9.1.2
.

3. No tabs on mail

pieces.

TAB READY light is

off. Peel point is free
of tabs and debris.

Toggle ON/OFF until

light illuminates.

4. FD 260 shuts

down. TAB
READY light
starts flashing.

Sensor could not find

tab during the pre-set
time.

Tune sensor. Refer to

Section 9.1.2.

5. Not tabbing --

TAB READY light
remains on,
multiple tabs
peeled.

Incorrect CLEAR TAB

selection.

Make CLEAR TAB

selection for tabs
being run. Refer to
Section 9.1.2.

6. Not tabbing --

TAB READY light
is on but no tabs
at peel point.

Sensor is blocked by

debris.

Remove debris from

the peel point area
through the inspection
window.