12

3.5 Accessory

Power Outlet

The ACCESSORY POWER OUTLET is located next
to the FUSEHOLDER on the non-operator side.
(Refer to Figure 3.1.) This outlet supplies power to
equipment running in-line with the FD 260.

Typical in-line equipment includes feeders and
labelers. Since the ACCESSORY POWER OUTLET
gets its power from the FD 260, you can control
power to in-line equipment using the FD 260

’s

POWER SWITCH. Additionally, the FD 260 features
an automatic interrupt that disables the ACCESSORY
POWER OUTLET in case of a jam. The
ACCESSORY POWER OUTLET is limited to a 6.3A
maximum for 100V and 120V, and 3.15A maximum
for 220V and 240V.

3.6 Power Cord

The FD 260 comes with a three-wire POWER CORD.
The POWER CORD grounds the FD 260 when
connected to an approved three-contact electrical
outlet.

1. Plug the POWER CORD into the APPLIANCE

INLET on the non-operator side. (Refer to Figure
3.1
.)

2. Plug the POWER CORD into a grounded outlet.

WARNING

TO PREVENT ELECTRICAL SHOCK, ONLY PLUG
THE POWER CORD INTO A GROUNDED OUTLET.