beautypg.com

Formax FD 260 User Manual

Page 15

background image

11

3.4 Accessory

Fuses

Two FUSEHOLDERS are located on the non-
operator side between the APPLIANCE INLET and
the ACCESSORY POWER OUTLET. (Refer to
Figure 3.1.) The FUSEHOLDERS hold two
ACCESSORY FUSES which protect the
ACCESSORY POWER OUTLET. As with the LINE
FUSES mentioned previously, both the neutral and
hot lines are fused. Both ACCESSORY FUSES must
be intact for the FD 260 to properly supply power to
in-line equipment.

WARNING

UNPLUG THE POWER CORD BEFORE STARTING

THIS PROCEDURE.


Use the following instructions to verify that the
ACCESSORY FUSES installed have the proper fuse
value or to replace a blown fuse:

1. Unplug the POWER CORD.

2. Use a small screwdriver or similar tool to press in

and rotate the FUSEHOLDER CAP
counterclockwise to release this cap.

3. Pull the FUSEHOLDER CAP (with the

ACCESSORY FUSE inside) out of the
FUSEHOLDER.

4. Verify the fuse value. Inspect fuses, replace if

blown.

Selected Voltage

Line Fuse Value

100V…………………… 6.3A (250V time delay)
120V…………………… 6.3A (250V time delay)
220V…………………… 3.15A (250V time delay)
240V (or 230V)……….. 3.15A (250V time delay)

5. Install the ACCESSORY FUSE and the

FUSEHOLDER CAP in the FUSEHOLDER. Both
ACCESSORY FUSES must be intact for the FD
260 to properly supply power to in-line equipment.

6. Using the screwdriver, press in and turn the

FUSEHOLDER CAP clockwise to lock it.