4.2.2 To adjust the Envelope Inserter settings
Unit Fine Tuning

All fine adjustments apply only to the current job and will not

affect any other jobs.

Select the inserter icon on

the machine graphic in the

Run screen to display the

fine tuning screen. Select

Hardware Fine Tuning to

display further information.

You can change:
a: The width of the collate

pocket guides.
b: The overall width of the

insert fingers.
c: The time allowed for

the flap to seal before the

envelope is ejected.
d: Adjustment of the point

at which the wetter beam

drops to wet the flap. +ve

increases wetting in 1mm

steps (moves start point

towards insertion area).
e: Adjustment of the point at which the wetter beam lifts. +ve increases duration,

ie. a greater length of flap is wetted befor the beam is lifted.
f. Adjustment of the amount of envelope travel into the sealing rollers. +ve = fur-

ther forward, away from exit direction.
g. Adjustment of the envelope stop position for insertion. +ve = further forwards,

towards exit direction.
h. Adjustment of the amount of insertion of the insert pack into the envelope. +ve

= further forwards past the flap crease.
i. Adjustment of the amount of envelope foward travel after flap wetting, before

reversing to enter the sealing rollers. +ve = further forward into the output rollers,

towards the exit direction. Note: for high-window envelopes, this should be

set to 20 - 50mm +ve.

When all adjustments are complete, select the ‘Unit’ button for hopper set-

tings, as described overleaf.