beautypg.com

2 alignment, Reading head position, English – Formax 6402 Series User Manual

Page 45

background image

43

ENGLISH

4.2.2

Alignment

Reading Head Position

The horizontal position of the reading head must be aligned to the same position of the
printed marks on the documents. To align the reading head, proceed as follows:

1. Open the “OMR test” menu from the “Test

menu” (refer to 2.4.6 ”Supervisor Menu” on
page 14).

2. Press

to start the alignment

procedure.

3. Put a document with reading marks in the

feeder (either feeder 1 or 2, depending on the
selected job).

4. Press .

The document will be transported to the reading
head position.

5. Open the special OMR reading head cover in the

feeder.

6. Shift the reading head until the red pointer is

positioned exactly above the middle of the
reading marks.

7. Open the vertical transport cover and remove the document.

8. Press

to determine the alignment.

9. Press

to finish the alignment procedure.

Note
When the reading head is aligned it is possible that paper guides have to be removed and
placed on the other side of the reading head.