background image

PCB-4300 1:2 Phase Combiner

Revision

2

Appendix B

MN/PCB4300.IOM

B–11

Parameter

Type

Command

(Instruction

Code and

qualifier)

Command

Valid for

PCB or

SSPA

Arguments

for

Command or

Response to

Query

Description of Arguments

(Note that all arguments are ASCII numeric codes –

i.e., ASCII codes between 48 and 57)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

qualifier)

Query

Valid for

PCB or

SSPA

Response to

Query

(Target to

Controller)

Retrieve
Maintenance
Status

N/A N/A

47 bytes,
alphanumeric

Query only.
Used to Query the maintenance status of the unit.

P24VT=024.1’cr’
P05VT=015.2’cr’
XXXXX=XXX.X’cr’
XXXXX=XXX.X’cr’’lf’

Note: XXXXX = reserved

N/A

RMS?

ALL

RMS=x….x
(see Description
of Arguments for
details)

Serial Number N/A

PCB

9 bytes,
numerical
000000000 to
999999999

Query only.

Used to Query the units 9 digit serial number.
Slave returns its S/N, in the form xxxxxxxxx.
Example: RSN=000000165

N/A

RSN?

ALL

RSN=xxxxxxxxx
(see Description
of Arguments for
details)

Retrieve
Utility Status

N/A N/A 17

bytes,

alphanumeric

Query only.
Used to Query the utility status of the unit
Example: RUS=’cr’

ADR=0001’cr’
BDR=9600’cr’’lf’

N/A

RUS?

ALL

RUS=x….x
(see Description
of Arguments for
details)

Remote Baud
Rate

SBR= PCB

4

bytes,

Command or Query.
Set remote baud rate as follows:
9600 = 9600 baud
19K2 = 19200 baud

SBR=
SBR?

SBR?

PCB

SBR=xx
(see Description
of Arguments for
details)

Summary
Fault Status

N/A N/A 1

byte,

value of 0,1

Query only.

Used to Query the status of the Summary Fault Relay.
Example: SFS=0 where:

0 = OK
1 = FT

N/A

SFS?

ALL

SFS=x
(see Description
of Arguments for
details)

Remote
Address

SPA= PCB

4

byte,

numerical

Command or Query.
Set Physical Address-between 0001 to 9999.
Resolution 0001
Example: SPA=0412

SPA=
SPA?

SPA?

ALL

SPA=x
(see Description
of Arguments for
details)

Set RTC Time TIM=

ALL 6

bytes,

numerical

Command or Query.
A command in the form hhmmss, indicating the time from
midnight, where hh = hours, between 00 and 23; mm = minutes,
between 00 and 59, and ss = seconds, between 00 and 59
Example: TIM=231259 would be 23 hours, 12 minutes and 59
seconds past midnight.

TIM =
TIM?
TIM *

TIM?

ALL

TIM=xx
(see Description
of Arguments for
details)