PCB-4300 1:2 Phase Combiner
Revision
2
Appendix B
MN/PCB4300.IOM
B–11
Parameter
Type
Command
(Instruction
Code and
qualifier)
Command
Valid for
PCB or
SSPA
Arguments
for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes –
i.e., ASCII codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
qualifier)
Query
Valid for
PCB or
SSPA
Response to
Query
(Target to
Controller)
Retrieve
Maintenance
Status
N/A N/A
47 bytes,
alphanumeric
Query only.
Used to Query the maintenance status of the unit.
P24VT=024.1’cr’
P05VT=015.2’cr’
XXXXX=XXX.X’cr’
XXXXX=XXX.X’cr’’lf’
Note: XXXXX = reserved
N/A
RMS?
ALL
RMS=x….x
(see Description
of Arguments for
details)
Serial Number N/A
PCB
9 bytes,
numerical
000000000 to
999999999
Query only.
Used to Query the units 9 digit serial number.
Slave returns its S/N, in the form xxxxxxxxx.
Example: RSN=000000165
N/A
RSN?
ALL
RSN=xxxxxxxxx
(see Description
of Arguments for
details)
Retrieve
Utility Status
N/A N/A 17
bytes,
alphanumeric
Query only.
Used to Query the utility status of the unit
Example: RUS=’cr’
ADR=0001’cr’
BDR=9600’cr’’lf’
N/A
RUS?
ALL
RUS=x….x
(see Description
of Arguments for
details)
Remote Baud
Rate
SBR= PCB
4
bytes,
Command or Query.
Set remote baud rate as follows:
9600 = 9600 baud
19K2 = 19200 baud
SBR=
SBR?
SBR?
PCB
SBR=xx
(see Description
of Arguments for
details)
Summary
Fault Status
N/A N/A 1
byte,
value of 0,1
Query only.
Used to Query the status of the Summary Fault Relay.
Example: SFS=0 where:
0 = OK
1 = FT
N/A
SFS?
ALL
SFS=x
(see Description
of Arguments for
details)
Remote
Address
SPA= PCB
4
byte,
numerical
Command or Query.
Set Physical Address-between 0001 to 9999.
Resolution 0001
Example: SPA=0412
SPA=
SPA?
SPA?
ALL
SPA=x
(see Description
of Arguments for
details)
Set RTC Time TIM=
ALL 6
bytes,
numerical
Command or Query.
A command in the form hhmmss, indicating the time from
midnight, where hh = hours, between 00 and 23; mm = minutes,
between 00 and 59, and ss = seconds, between 00 and 59
Example: TIM=231259 would be 23 hours, 12 minutes and 59
seconds past midnight.
TIM =
TIM?
TIM *
TIM?
ALL
TIM=xx
(see Description
of Arguments for
details)