beautypg.com

Comtech EF Data PCB-4300 User Manual

Page 85

background image

PCB-4300 1:2 Phase Combiner

Revision

2

Appendix B

MN/PCB4300.IOM

B–7

Parameter

Type

Command

(Instruction

Code and

qualifier)

Command

Valid for

PCB or

SSPA

Arguments

for

Command or

Response to

Query

Description of Arguments

(Note that all arguments are ASCII numeric codes –

i.e., ASCII codes between 48 and 57)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

qualifier)

Query

Valid for

PCB or

SSPA

Response to

Query

(Target to

Controller)

Automatic
Gain Initialize

AGI= PCB

0

bytes,

alphanumeric

Command only.
Initializes all gains for the attenuation offset.
This command takes no arguments.

AGI=
AGI?
AGI*

N/A

N/A

N/A

RF Power
Amplifier State

AMP= PCB 1

byte,

value of 0, 1

Command or Query
Turns ON or OFF the SSPAs in the form AMP=x, where:
0 = Off
1 = On

AMP=
AMP?
AMP*

AMP?

ALL

AMP=x
(see Description
of Arguments for
details)

Attenuation
Offset

AOF= PCB

7

bytes,

alphanumeric

Command or Query
Sets attenuation offset for specified SSPA
Command: AOF=x,yy.yy
Query: AOF?x
where: x=1, 2, or 3 (SSPA number)

yy.yy=Attenuation offset

Example: AOF=1,01.50
Note: AOF command will not take values greater than 6 dB)

AOF=
AOF?
AOF*

AOF?x
where x=1,2, or 3

PCB

AOF=x,yy.yy
(see Description
of Arguments for
details)

Attenuation

ATT= PCB

5

bytes,

numerical

Command or Query.
Valid attenuation level, in dB, at 0.25-dB step size as factory
default.
Example: ATT=12.25
Note: The attenuation range is limited to a maximum of 24 dB.

ATT=
ATT?
ATT*

ATT?

ALL

ATT=xx.xx
(see Description
of Arguments for
details)

Clear All
Stored Alarms

CAA=

ALL None Command

only

Instructs the slave to clear all Stored Events.
This command takes no arguments.

CAA=

N/A

N/A

N/A

Concise
Alarm Status

N/A N/A 11

bytes

numerical with
commas

Query only.

Used to Query the Alarm status of the unit, response is comma
delimited.
Example: CMS=a,b,c,d,e,f,g’cr’’lf’ where:

a thru k = 0 or 1, 0 = OK 1 = FT
a = +24V Power Supply
b = +5V Power Supply
c = SSPA1
d = SSPA2
e = SSPA3
f = SW1 Absent FLT
g = SW2 Absent FLT

N/A

CAS?

ALL

CAS=x….x
(see Description
of Arguments for
details)