B.5.6 Optional Message Arguments
Arguments are not required for all messages. Arguments are ASCII codes for the characters 0 to 9 (ASCII codes 48 to 57), period (ASCII
code 46) and comma (ASCII code 44).
B.5.7 End Of Packet
Controller-to-Target: This is the ‘Carriage Return’ character (ASCII code 13).
Target-to-Controller: This is the two-character sequence ‘Carriage Return’, ‘Line Feed’ (ASCII codes 13 and 10).
Both indicate the valid termination of a packet.
B.6
Remote Commands / Queries
Index Notes: Column ‘C’ = Command; Column ‘Q’ = Query; columns marked ‘X’ designate instruction code as Command only, Query only, or Command/Query.
CODE
C
Q
PAGE
CODE
C
Q
PAGE CODE
C
Q
PAGE CODE
C
Q
PAGE
A
D
P
S
AGI
X B-7
DAT
X X B-8
PRF
X X B-9
SBR
X X B-11
AMP
X X B-7
SFS
X B-11
AOF
X X B-7
SPA
X X B-11
ATT
X X B-7
F
R
FRC
X X B-8
RAS
X B-10
T
FRW
X B-9
RCS
X B-10
TIM
X X B-11
C
RET
X B-10
TNA
X B-12
CAA
X B-7
L
RMS
X B-11
CAS
X B-7
LNA
X B-9
RSN
X B-11
CCS
X B-8
RUS
X B-11
CID
X X B-8
CMS
X B-8
M
CUS
X B-8
MUT
X X B-9
Unless otherwise noted – In the tables that follow, these codes are used in the ‘Response to Command’ column (per Sect. B.5.6)
= Message ok
? Received ok, but invalid arguments were found
* Message ok, but not permitted in current mode