beautypg.com

Comtech EF Data PCB-4300 User Manual

Page 86

background image

PCB-4300 1:2 Phase Combiner

Revision

2

Appendix B

MN/PCB4300.IOM

B–8

Parameter

Type

Command

(Instruction

Code and

qualifier)

Command

Valid for

PCB or

SSPA

Arguments

for

Command or

Response to

Query

Description of Arguments

(Note that all arguments are ASCII numeric codes –

i.e., ASCII codes between 48 and 57)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

qualifier)

Query

Valid for

PCB or

SSPA

Response to

Query

(Target to

Controller)

Concise
Configuration
Status

N/A N/A 24

bytes

numerical

Query only.
Used to query the summarized version of RCS.
Example: CCS=aa.aa,b,c,d,e,f,g,x‘cr’’lf’ where:

aa.aa = attenuation in dB
b = RF power amplifier state
c = mute state
d = reserved
e,f,g,x = SSPAs fault status

N/A

CCS?

ALL

CCS=x….x
(see Description
of Arguments for
details)

Circuit
Identification

CID= PCB

24

bytes,

alphanumeric

Command or Query
Used to identify or name the unit or station.

CID=
CID?

CID?

ALL

CID=x…x
(see Description
of Arguments for
details)

Concise
Maintenance
Status

N/A N/A 23

bytes

numerical

Query only.

Used to Query the Maintenance status of the unit in concise
format. Response is comma delimited.
Example: CMS=aaa.a,bbb.b,ccc.c,ddd.d’cr’’lf’ where:

aaa.a = +24V Power Supply
bbb.b = +5V Power Supply
ccc.c = reserved (XXX.X)
ddd.d = reserved (XXX.X)

N/A

CMS?

ALL

CMS=x….x
(see Description
of Arguments for
details)

Concise
Utility Status

N/A N/A 11

bytes,

alphanumeric

Query only.
Used to Query the Maintenance status of the unit, response is
comma delimited.
Example: CUS=aaaa,bbbb’cr’’lf’ where:

aaaa = Remote Unit Address
bbbb = Remote Baud Rate

N/A

CUS?

ALL

CUS=x….x
(see Description
of Arguments for
details)

Set RTC(Real-
Time-Clock)
Date

DAT=

ALL 6

bytes,

numerical

Command or Query.
A command in the form mmddyy, where; dd = day of the month,
between 01 and 31, mm = month of the year, between 01 and 12
and yy = year, between 00 and 99 (2000 to 2099)
Example: DAT=042503 would be April 24, 2003

DAT=
DAT?
DAT*

DAT?

ALL

DAT=xx
(see Description
of Arguments for
details)

Force Unit
Online

FRC=

PCB

2 bytes

Command or Query.
Force two SSPA’s to be online, in the form FRC=xy where:

xy = 12 (SSPAs 1 and 2)

23 (SSPAs 2 and 3)
13 (SSPAs 1 and 3)
00 (Automatic mode)

FRC=

FRC?

FRC?

PCB

FRC=xy
(see Description
of Arguments for
details)