2 monitor and control (m&c) interface connectors, 1 system com j1 connector – Comtech EF Data PCB-4300 User Manual
Page 25
PCB-4300 1:2 Phase Combiner
Revision 2
External Connectors
MN/PCB4300.IOMMN/PCB4300.IOM
2–3
2.2
Monitor and Control (M&C) Interface Connectors
Note: All M&C connectors are found on the front panel of the PCCB box.
2.2.1
SYSTEM COM J1 Connector
The SYSTEM COM J1 connector is a 19-pin circular connector, type
MS3112E14-19S. It serves as the primary input between the user and the PCCB
for controlling and monitoring both SSPAs. Its pinout specification is provided in
Table 2-2.
Mating connector: ITT Cannon MS3116J14-19P
(CEFD P/N CN/MS3116J14-19P).
Table 2-2. Connector J1 Pinouts
Pin # Signal Function
Signal Name / Description
A RS485_+RX
Customer
communications
interface
B RS485_-RX
Customer
communications
interface
C RS485_+TX
Customer
communications
interface
D RS485_-TX
Customer
communications
interface
E RS232_RD
Customer
communications
interface
F
Spare
Reserved for future use
G RS232_TD
Customer
communications
interface
H
System Fault NO
When there is a summary fault in the PCB-4300, this pin (NO) will be tied to the Fault
Common pin.
J
System Fault NC
When there is not a summary fault in the PCB-4300, this pin (NC) will be tied to the Fault
Common pin.
K Fault
Common
L
SSPA 1 Fault NO
When there is a fault with SSPA 1, this pin (NO) will be tied to the Fault Common pin.
M
SSPA 1 Fault NC
When there is not a fault with SSPA 1, this pin (NC) will be tied to the Fault Common pin.
N Ground
P
SSPA 2 Fault NO
When there is a fault with SSPA 2, this pin (NO) will be tied to the Fault Common pin.
R
SSPA 2 Fault NC
When there is not a fault with SSPA 2, this pin (NC) will be tied to the Fault Common pin.
S
System Mute
SSPA will be muted if this pin is grounded
T
SSPA 3 Fault NO
( NOTE: This pin is reserved for use with 1:2 systems only.)
U
SSPA 3 Fault NC
( NOTE: This pin is reserved for use with 1:2 systems only.)
V Ground
GND