beautypg.com

Comtech EF Data PCB-4300 User Manual

Page 88

background image

PCB-4300 1:2 Phase Combiner

Revision

2

Appendix B

MN/PCB4300.IOM

B–10

Parameter

Type

Command

(Instruction

Code and

qualifier)

Command

Valid for

PCB or

SSPA

Arguments

for

Command or

Response to

Query

Description of Arguments

(Note that all arguments are ASCII numeric codes –

i.e., ASCII codes between 48 and 57)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

qualifier)

Query

Valid for

PCB or

SSPA

Response to

Query

(Target to

Controller)

Retrieve
Alarm Status

N/A N/A 53

bytes

alphanumeric

Query only.

Used to Query the Alarm status of the unit.
Example: RAS=’cr’

P24VT=OK’cr’
P5VLT=OK’cr’
SSPA1=OK’cr’
SSPA2=OK’cr’
SSPA3=OK’cr’
SW1FT=OK’cr’
SW2FT=OK’’cr’’lf’

Note: XXXXX = reserved

N/A

RAS?

ALL

RAS=x….x
(see Description
of Arguments for
details)

Retrieve
Configuration
Status

N/A N/A 33

bytes

alphanumeric

Query only.
Used to Query the configuration status.
Example: RCS=’cr’

ATT=12.75’cr’
AMP=1’cr’
MUT=1’cr’
PCM=1,0’cr’
FLT=0,0,X’cr’’lf’

where:

ATT= attenuation in dB
AMP= RF power amplifier state, 0=OFF, 1=ON
MUT=RF mute state, 0=unmuted, 1=muted
PCM=reserved
FLT=X,Y,Z (SSPA fault states)
X = SSPA#1 (1=faulted, 0=unfaulted)
Y = SSPA#2 (1=faulted, 0=unfaulted)
Z = SSPA#3 (1=faulted, 0=unfaulted)

N/A

RCS?

ALL

RCS=x….x
(see Description
of Arguments for
details)

Retrieve
Equipment
Type

N/A N/A 20

bytes,

alphanumerical

Query only.
The unit returns a string indicating the Model Number and the
value of internal software revision installed.
Example: Phase –Combine Ver. 1.1.16I or
KPA-100-1415 VER:1.1.3

N/A

RET?

ALL

RET=x….x
(see Description
of Arguments for
details)