Stored alarm, B.6.5 stored alarm – Comtech EF Data UT-4579 User Manual
Page 81
UT4579 X-Band Up Converter
MN/UT4579.IOM
Remote Control
Rev. 0
65
B.6.4.10 P
ACKED
A
LARM
S
TATUS
Packed Alarm Status:
Confirmation:
>DEV/PACRAS_abcdefghijk'cr''lf']
where:
a = 1 if V15 Fault, else 0
b = 1 if V14 Fault, else 0
c = 1 if VCC Fault, else 0
d = 1 if V5D Fault, else 0
e = 1 if TEMP Fault, else 0
f = 1 if IFLO Fault, else 0
g = 1 if SUM Fault, else 0
h = 1 if COARSE Fault, else 0
I = 1 if FINE Fault, else 0
j = 1 if HSB Fault, else 0
k = 1 if EXT REF Fault, else 0
B.6.5 S
TORED
A
LARM
The 100 alarms are date/time stamped and stored in memory as they occur. The alarm
entry is also updated with its date/time of clearance. The entry remains in memory until
it is removed by command.
B.6.5.1 T
OTAL
S
TORED
A
LARMS
This command retrieves the total number of stored alarms and the time and date of the
most recent alarm.
Retrieve Total Alarms:
Confirmation: >DEV/TSA_TOTAL:nn'cr' LAST:hh:mm:ss mm/dd/yy'cr''lf'] where: nn = 0 to 99; the 100 th alarm will be ER hh.mm.ss = time in hour:minute:second mm/dd/yy = date in month/day/year B.6.5.2 C LEAR A LL S TORED A LARMS Clear Alarms: Confirmation: >DEV/CAA_CLEARED'cr''lf']