Modes, B.6.3 modes, B.6.2.8 c – Comtech EF Data UT-4579 User Manual
Page 75: B.6.2.9 s, B.6.3 m, B.6.3.1 r
UT4579 X-Band Up Converter
MN/UT4579.IOM
Remote Control
Rev. 0
59
B.6.2.8 C
LEAR
P
RESET
This command is used to clear a preset number.
Command
Details
Clear a Preset:
Confirmation: >DEV/CLR_nn_Cleared'cr''lf']
Note: nn = Preset Number = 01 to 32.
B.6.2.9 S
ELECT A
P
RESET
This command is used to configure the converter to the frequency and attenuation data
assigned to a given preset number.
Command
Details
Select Preset:
Confirmation: >DEV/SEL_nn_Selected'cr''lf']
Note: nn = Preset Number = 01 to 32.
Only programmed preset numbers are available.
B.6.3 M
ODES
There are two modes of operation that may intersect: Redundant Mode and Automatic
Mode.
B.6.3.1 R
EDUNDANCY
M
ODE
Since the default mode is OFF, each converter including the backup converter
must be commanded into the Redundancy Mode.
Polling on the high speed bus will not begin until the position assignments are
made.
Command
Details
Redundancy Mode:
xxx = ON or OFF Confirmation: >DEV/RED_xxx'cr''lf'] Redundancy Status: Confirmation: >DEV/RED_xxx'cr''lf'] Each converter's chain position must be initialized including the backup converter. The
following redundancy initialization command is only allowed if Redundancy Mode has
been selected.