UT4579 X-Band Up Converter

MN/UT4579.IOM

Installation

Rev. 0

12

2.4.3 H

IGH

S

PEED

B

US

(HSB), C

ONNECTOR

J3

The High Speed Bus connector, J3, is 25 pin "D" type DB25F connector socket. The pin-
out specifications is contained in Table 6. The mating connector is a DB25M.

Note: This is not a “straight through” cable assembly. Contact Comtech EF Data for detailed

wire drawings when cabling between converters.

Table 6. J3, High Speed Bus Connector Pin-Out

Pin #

Description

Pin # Description

Pin #

Description

1 Cntl_12

10

Aux_3

18

Cntl_3

2 Cntl_10

11

Aux_1

19

Cntl_1

3 Cntl_8

12

-Rx/Tx

20

+14V

Out

4 Cntl_6

13

GND

21

+14V

In

5 Cntl_4

14

Cntl_11

22

GND

6 Cntl_2

15

Cntl_9

23

Aux_2

7 Cntl_In

16

Cntl_7

24

GND

8 +14V

Out

17

Cntl_5

25

+Rx/Tx

9 +14V

In

2.4.4 S

UMMARY

F

AULT

O

UTPUT

(RELAY), C

ONNECTOR

P1

The summary fault output connector, P1, is 9 pin "D" type DB9M connector. The pin-
out specifications are contained in Table 7. The mating connector is a DB9F.

Table 7. P1, Summary Fault Connector Pin-Out

Pin # Description

1

Summary Fault NC

2

Summary Fault NO

3

4

5 Ground

6

Summary Fault Com

7

External Fault Input

8

9

Notes:

1

Pin 1 to Pin 6: Fault.

2

Pin 2 to Pin 6: No Fault.

3