MN/UT4579.IOM

Redundant System Operation

Rev. 0

42

A.4.3 M

ANUAL

C

ONFIGURATION

/V

ERIFICATION

Figure 31 shows the system with converter #1 configured for manual(M) operation. In
this mode, the backup converter can force switchover of an online unit. This mode also
overrides fault status detection of the online units performed by the backup converter.
If an online unit is configured to manual mode and this unit faults, no switchover will
occur.

-CONVERTER-123456789ABC-

-AUTO/MAN-MAA-----------

POWER ON

TRANSMIT

REMOTE

ON LINE

FAULT

STORED FAULT

STATUS

POWER ON

TRANSMIT

REMOTE

ON LINE

FAULT

STORED FAULT

STATUS

POWER ON

TRANSMIT

REMOTE

ON LINE

FAULT

STORED FAULT

STATUS

POWER ON

TRANSMIT

REMOTE

ON LINE

FAULT

STORED FAULT

STATUS

FREQ= 79XX.XXX-MHz-MAN--

ATTN= 10.00-DB---Tx=ON--

FREQ= 79XX.XXX-MHz-AUTO-

ATTN= 10.00-DB---Tx=ON--

FREQ= 79XX.XXX-MHz-AUTO-

ATTN= 10.00-DB---Tx=ON--

Figure 31. Converter #1 in MANUAL, Others in AUTO