UT4579 X-Band Up Converter
MN/UT4579.IOM
Redundant System Operation
Rev. 0
42
A.4.3 M
ANUAL
C
ONFIGURATION
/V
ERIFICATION
Figure 31 shows the system with converter #1 configured for manual(M) operation. In
this mode, the backup converter can force switchover of an online unit. This mode also
overrides fault status detection of the online units performed by the backup converter.
If an online unit is configured to manual mode and this unit faults, no switchover will
occur.
-CONVERTER-123456789ABC-
-AUTO/MAN-MAA-----------
POWER ON
TRANSMIT
REMOTE
ON LINE
FAULT
STORED FAULT
STATUS
POWER ON
TRANSMIT
REMOTE
ON LINE
FAULT
STORED FAULT
STATUS
POWER ON
TRANSMIT
REMOTE
ON LINE
FAULT
STORED FAULT
STATUS
POWER ON
TRANSMIT
REMOTE
ON LINE
FAULT
STORED FAULT
STATUS
FREQ= 79XX.XXX-MHz-MAN--
ATTN= 10.00-DB---Tx=ON--
FREQ= 79XX.XXX-MHz-AUTO-
ATTN= 10.00-DB---Tx=ON--
FREQ= 79XX.XXX-MHz-AUTO-
ATTN= 10.00-DB---Tx=ON--
Figure 31. Converter #1 in MANUAL, Others in AUTO