B.5.5 E

RROR

R

ESPONSE

If a converter cannot execute a Command or detects a protocol violation, an error
response is generated. An error is flagged by changing the "/" command designator in the
response to a "?". Following the "?" error symbol are two characters which are unique
error symbols useful for computer analysis. The two error symbols are followed by a text
string explaining the error for the convenience of a human operator. For this document
ER is used for the generic case examples response.
Example:

>DEV?COM ER Error Message 'cr''lf']

B.5.6 E

ND

O

F

M

ESSAGE

End of message strings were devised in such a way that an orderly screen presentation
would result when Converter is controlled by simple ASCII terminals.

B.5.6.1 C

OMMAND

E

NDING

The end of message for a command is a carriage return. For this document 'cr' is used for
the carriage return.
Example:

B.5.6.2 R

ESPONSE

E

NDING

End of message for a response is a carriage return, line feed and a bracket: 'cr''lf'].