Error response, End of message, B.5.5 error response b.5.6 end of message – Comtech EF Data UT-4579 User Manual
Page 68
UT4579 X-Band Up Converter
MN/UT4579.IOM
Remote Control
Rev. 0
52
B.5.5 E
RROR
R
ESPONSE
If a converter cannot execute a Command or detects a protocol violation, an error
response is generated. An error is flagged by changing the "/" command designator in the
response to a "?". Following the "?" error symbol are two characters which are unique
error symbols useful for computer analysis. The two error symbols are followed by a text
string explaining the error for the convenience of a human operator. For this document
ER is used for the generic case examples response.
Example:
>DEV?COM ER Error Message 'cr''lf']
B.5.6 E
ND
O
F
M
ESSAGE
End of message strings were devised in such a way that an orderly screen presentation
would result when Converter is controlled by simple ASCII terminals.
B.5.6.1 C
OMMAND
E
NDING
The end of message for a command is a carriage return. For this document 'cr' is used for B.5.6.2 R ESPONSE E NDING End of message for a response is a carriage return, line feed and a bracket: 'cr''lf'].
the carriage return.
Example:
Example: >DEV/COM_'cr''lf']