beautypg.com

B.6.1.5 lcd c, B.6.1.6 lcd b, B.6.1.7 r – Comtech EF Data UT-4579 User Manual

Page 70: B.6.1.8 c

background image

UT4579 X-Band Up Converter

MN/UT4579.IOM

Remote Control

Rev. 0

54

B.6.1.5 LCD C

ONTRAST

The default is 15.

Command

Details

Set Contrast:

_xx'cr'

xx = 0 to 30

Confirmation: >DEV/CON_xx'cr''lf']

Retrieve Contrast:

_'cr'

Confirmation: >DEV/CON_xx'cr''lf']

B.6.1.6 LCD B

RIGHTNESS

The default is 15.

Command

Details

Set Brightness

xx = 0 to 30

Confirmation: >DEV/LCD_xx'cr''lf']

Retrieve Brightness:

_'cr'

Confirmation: >DEV/LCD_xx'cr''lf']

B.6.1.7 R

EFERENCE

O

SCILLATOR

T

UNING

The default is 87.

Command

Details

Set Oscillator:

_xxx'cr'

xxx = 0 to 255

Confirmation: >DEV/SRO_xxx'cr''lf']

Retrieve Tuning:

_'cr'

Confirmation: >DEV/SRO_xxx'cr''lf']

B.6.1.8 C

ONVERTER

S

LOPE

A

DJUSTMENT

The default is 0.3.

Command

Details

Set Slope Adjust:

_xxx'cr'

xxx = 0.0 to 1.0

Confirmation: >DEV/SSA_xxx'cr''lf']

Retrieve Slope Adjust:

_'cr'

Confirmation: >DEV/SSA_xxx'cr''lf']