MN/UT4579.IOM
Remote Control
Rev. 0
61
B.6.3.3 B
ACKUP
M
ODE
This command allows the user to force a backup condition for maintenance and test
purposes. This command must be sent to the converter designated as the backup
converter (i.e., “BU”). When activated this command forces the backup converter to
assume the state of the specified chain converter and forces the chain converter offline.
Command
Details
Initiate a Backup:
Confirmation: >DEV/FBU_xx_y'cr''lf'] Where: xx = 01 to 12, converter number y = ‘F’ to force a backup ‘N’ to remove a backup Retrieve Backup Confirmation: >DEV/FBU_xx_zzzzz'cr''lf'] Where: xx = 01 to 12, converter number. If zzzzz = NONE, converter number is not displayed. zzzzz = ‘NONE’ if no backup active = ‘ACTIVE’ if an automatic backup has occurred = ‘FORCED’ if a forced backup is active B.6.4 S TATUS C OMMANDS Status commands retrieve configuration, maintenance and alarm status in summary form. B.6.4.1 C ONFIGURATION S TATUS Command Details Configuration Status: Confirmation: >DEV/RCS_'cr' FRE_xxxxx.xxx'cr' Frequency ATT_yy.yy'cr' Attenuator TX_nnn'cr' Transmitter - ON/OFF/COLD ONL_nnn'cr' Online - ON/OFF RED_xx_yy_z'cr' See Note CLD_nnn'cr' Cold Start - ON/OFF AFR_nnn'cr' Auto Flt Recovery-ON/OFF EXT_xxx'cr''lf'] Ext. Ref. - YES/NO Note: If Redundancy OFF xx_yy_z = OFF, else if Redundancy ON and converter selected as backup controller xx_yy_z = BU_yy where yy is the number of converters in the chain
Status:
(i.e. 01 to 12), else if Redundancy ON and converter selected as a chain unit xx is the
converter number (01 to 12), and z = A if Auto Mode or M if Manual Mode.