B.6.4.2 m, B.6.4.3 u, B.6.4.4 a – Comtech EF Data UT-4579 User Manual
Page 78
UT4579 X-Band Up Converter
MN/UT4579.IOM
Remote Control
Rev. 0
62
B.6.4.2 M
AINTENANCE
S
TATUS
Command
Details
Maintenance Status:
Confirmation: >DEV/RMS_'cr' P15_xx.x'cr' 15 Vdc Supply P14_xx.x'cr' 14 Vdc Supply VCC_x.x'cr' VCC Supply 5VD_x.x'cr' Display 5 Vdc TEM_xx'cr' Temperature IFL_xx.x'cr' IFLO Tuning SUM_xx.x'cr' Sum Loop Tuning COR_xx.x'cr' Coarse Loop Tune FIN_xx.x'cr''lf'] Fine Loop Tuning. B.6.4.3 U TILITY S TATUS Command Details Utility Status: Confirmation: >DEV/RUS_'cr' COMM_aaaaaa'cr' EIA-232C or EIA-485 ADD_xxx'cr' Address (001 to 255) BR_nnnn'cr' Baud Rate (1200, 2400, 4800, 9600, 19K2, or 38K4) FMT_x-y-z’cr’ Data Format x=data, y=parity, z=stop bit (8-N-1, 7-E-2, 7-O-2) REF_xxx'cr' Osc. Adjust (000 to 255) SLP_x.x'cr' Slope Adjust (0.0 to 1.0) CON_xx'cr' LCD Contrast (0 to 30) LCD_xx'cr''lf'] LCD Brightness (0 to 30). B.6.4.4 A LARM S TATUS Command Details Alarm Status: Confirmation: >DEV/RAS_'cr' P15_xx'cr' 15 Vdc Fault P14_xx'cr' 14 Vdc Fault VCC_xx'cr' VCC Fault 5VD_xx'cr' 5VD Fault TEM_xx'cr' Temperature Fault IFL_xx'cr' IFLO Lock Fault SUM_xx'cr' Sum Lock Fault COR_xx'cr' Coarse Lock Fault FIN_xx'cr' Fine lock Fault HSB_xx’cr’ High Speed Bus Fault *REF_xx'cr''lf'] Ref. Lock Fault xx = OK or FT Note: REF_xx is only returned if an external reference is present.