Stored faults, 6 stored faults – Comtech EF Data UT-4579 User Manual
Page 44

UT4579 X-Band Up Converter
MN/UT4579.IOM
System Operation
Rev. 0
28
3.3.5.3 S
YNTHESIZER
F
AULTS
Displays the synthesizer faults:
Sum Loop Detect.
Coarse Loop Detect.
Fine Loop Detect.
3.3.5.4 C
ONVERTER
O
VER
T
EMPERATURE
F
AULT
Displays a converter temperature fault condition.
3.3.6 S
TORED
F
AULTS
The converter displays a total of 100 faults which are date and time stamped and stored in
memory as they occur. The stored faults remain in memory until a clear command is
entered. When the number of faults reaches 100, the 100
th
fault will display ER.
3.3.6.1 T
OTAL
S
TORED
F
AULTS
Displays the total number of faults stored. The most recent fault stored is displayed on
the LCD display.
3.3.6.2 C
LEAR
A
LL
S
TORED
F
AULTS
Input command to clear all faults. The command is "YES" or "NO' which is displayed on
the LCD display.
3.3.6.3 D
ISPLAY
S
TORED
F
AULT
The local operator can sequence through the stored faults starting with the most recent
fault. The fault number, time, description and date is displayed on the LCD display.