Command / response pairs, Utility commands, B.6 command / response pairs – Comtech EF Data UT-4579 User Manual

Page 69: B.6.1 utility commands, B.6 c, B.6.1 u, B.6.1.1 t, B.6.1.2 d, B.6.1.3 p, B.6.1.4 b

background image

UT4579 X-Band Up Converter

MN/UT4579.IOM

Remote Control

Rev. 0

53

B.6 C

OMMAND

/ R

ESPONSE

P

AIRS

B.6.1 U

TILITY

C

OMMANDS

B.6.1.1 T

IME

Command

Details

Set Time:

_hh:mm:ss'cr'

hh = Hour*

Confirmation: >DEV/TIM_hh:mm:ss'cr''lf']

mm = Minutes ss = Seconds

Retrieve Time:

_'cr'

Confirmation: >DEV/TIM_hh:mm:ss'cr''lf']

* 24 hour military time is used.

B.6.1.2 D

ATE

Command

Details

Set Date:

mm = Month

Confirmation:

>DEV/DAT_mm/dd/yy'cr'lf']

dd = Day

yy = Year

Retrieve Date:

_'cr'

Confirmation: >DEV/DAT_mm/dd/yy'cr''lf']

B.6.1.3 P

HYSICAL

A

DDRESS

The default Physical Address from is 1.

Command

Details

Set Physical Address:

xxx = 1 to 255

Confirmation: >DEV/SPA_xxx'cr''lf']

Retrieve Phys. Addr:

Confirmation: >DEV/SPA_xxx'cr''lf']

B.6.1.4 B

AUD

R

ATE

The default baud rate is 9600.

Command

Details

Set Baud Rate:

xxxx = 1200, 2400, 4800, 9600, 19K2, or 38K4

Confirmation: >DEV/SBR_xxxx'cr''lf']

Retrieve Baud Rate:

_xxxx'cr'