Appendix A. Remote Control

Operation

This appendix describes the remote control operation of the SDR-54A.

• Firmware

number: FW/5445-1K

• Software

version: 4.2.4

A.1 General

Remote controls and status information are transferred via an EIA-232 serial
communications link.

Commands and data are transferred on the remote control communications link as
US ASCII-encoded character strings.

The remote communications link is operated in a half-duplex mode.

Communications on the remote link are initiated by a remote controller or terminal. The
modem never transmits data on the link unless it is commanded to do so.

A.2 Message

Structure

The ASCII character format used requires 9600 bits/second, 11 bits/character:

• 1 start bit
• 7 information bits
• 1 parity bit (even)
• 2 stop bits

A–1