beautypg.com

48 vdc option, 24 vdc option, Ground (gnd) – Comtech EF Data SDR-54A User Manual

Page 29: 2 48 vdc option, 3 24 vdc option, 6 ground (gnd)

background image

SDR-54A Satellite Demodulator

Revision 4

External Connectors

MN/SDR54A.IOM

3.1.5.2

48 VDC Option

Table 3-9. 48 VDC Option

Parameter

Specification

Connector Type

20A 3-way screw-type terminal block.

Input Power

40W maximum.

Input Voltage

46 to 50 VDC.

Fuse Protection
(internal on power supply)

2A slo-blo.

3.1.5.3

24 VDC Option

Table 3-10. 24 VDC Option

Parameter

Specification

Connector Type

20A 3-way screw-type terminal block.

Input Power

40W maximum.

Input Voltage

23 to 25 VDC.

Fuse Protection
(Internal on power supply)

2A slo-blo.

3.1.6 Ground (GND)

A #10-32 stud is available on the rear for connecting a common chassis ground among all
of the equipment.

Note: The safety ground is provided through the AC power connector.


















3–7