beautypg.com

Comtech EF Data MIDAS Version 4.X NMS Configuration User Manual

Page 75

background image

MIDAS 4.X NMS Configuration, Rev.6

Setup and Operation 2–47

If a value of zero is entered for the Carrier Loss Timeout, the node controller will use its
default value of two seconds.

IMPORTANT

The following screen is only applicable to EF Data Type SDM-modems.

Automatic Uplink Power Control can only be viewed when channel is Inactive. For
Comtech EF Data CDM-modems, the N/A Sections will be ‘GREYED’ out.

AUPC Settings

Comtech Modem

Parameter

Range

Default

Range

Default

Max Power (delta from
nominal)

+3 to +20 db

+10 db

O to 9 dB

1

Min Power (delta from
nominal)

-3 to -20 db

-10 db

N/A

3

Target Eb/N0

3.2 to 16.0 db

12 db

0 to 9 .9 dB

Max Tracking Rate

0.5 to 6.0 db/min

2.0 db/min

N/A

Carrier Loss Local Action

(Hold,Nominal,Max)

Max

N/A

Carrier Loss Remote Action (Hold,Nominal,Max)

Max

Nominal, Max

Nominal, Max

Carrier Loss Timeout

0 to 255 sec

0

0 to 255

0