beautypg.com

Comtech EF Data MIDAS Version 4.X NMS Configuration User Manual

Page 34

background image

MIDAS 4.X NMS Configuration, Rev.6

2–6

Setup and Operation

Satellite Name

Enter Satellite name.

System Parameters:

Allocation Factor

This is a factor, or multiplier, used as a carrier spacing placed between carrier assignments to
avoid interference (roll-offs, skirts). A typical Allocation Factor is 1.4. Using a larger number will
provide a larger spacing, but will also take up valuable transponder space.

Step Size

This is the smallest unit of bandwidth that will be displayed and allocated on the Space Segment.
Range: 2.5 to 25.0 kHz, in 2.5 kHz increments.

Keep Logs for

This parameter sets the number of days that logs will be kept before they are deleted from the
system.

Lock Time

This sets the amount of time, in seconds, that a node will wait after a circuit is successfully
established before checking the traffic modems for loss of carrier. It is only after this "stabilization"
period that the node sends a terminate message back to the NMS if the circuit failed due to
carrier loss.

Event Monitor/Summary Bar
Setting

Event Auto-
Acknowledgement
Time

Enter number of minutes for events displayed in Summary Bar to be automatically acknowledged.
Max 1440 (24 hours) Min 0 (No Auto Acknowledgement). For best NMS performance, it is
recommended to enable Auto-Ack. All events will be available in the Event Browser.

View Completed Calls
for Past

Select how often to reset completed calls in Summary Bar – by number of minutes (1440 – 0) or
by number of calls (1 – 1000).