Redundant System Installation

KST-12025 Ku-Band Satellite Terminal

3–14

Rev. 1

6. Mount the RFTs as follows:

a.

Lift the RFT into position on
the vertical pole.

b. Slip a 14” unistrut over each

of pair of threaded rods
(upper and lower).

Note: Install the 14” unistruts
with the open face toward the
pole, as illustrated.

c.

Install a 5/16” flat washer,
5/16” split lockwasher, and
5/16-18 nut on each threaded
rod.

d. Position the RFT, as desired,

and tighten the 5/16-18 nuts
installed in Step 6.c.

e.

Slide the pipe blocks in until
they contact the vertical pole.

Then, firmly tighten the
5/16-18 bolts.

3.3.2.2 Square

Pole

For square vertical pole installation, follow the steps in Section 3.3.2.1, with the
following exceptions:

Do not perform Step 4.

Do not perform Step 6.e.