Down converter, 5 down converter, Figure 5-6. down converter synthesizer diagram – Comtech EF Data KST-12025 User Manual

Page 100: Figure 5-7. up converter synthesizer diagram

background image

Theory of Operation

KST-12025 Ku-Band Satellite Terminal

5–14

Rev. 1

10 MHz REFERENCE

M&C BUS

LO REFERENCE

DOWNLINK SYNTH RF OUTPUT

SMA FEMALE
CMOS LEVELS
SQUARE WAVE

2300 MHz
SMA FEMALE
-7 dBm

+12 VDC
FREQUENCY CONTROL
VCO TUNING VOLTAGE MONITORS
LOCK DETECT SIGNALS

SMA FEMALE
+8 dBm
9730 to 11530 MHz
(10.95 to 12.75 GHz RCV)
9730 to 10480 MHz
(10.95 to 11.7 GHz RCV)
10480 to 10980 MHz
(11.7 to 12.2 GHz RCV)
11030 to 11530 MHz
(12.25 to 12.75 GHz RCV)

Figure 5-6. Down Converter Synthesizer Diagram

10 MHz REFERENCE

M&C BUS

LO REFERENCE

U/C RF LO

SMA FEMALE
CMOS LEVELS
SQUARE WAVE

2300 MHz
SMA FEMALE
-4 dBm

+12 VDC
FREQUENCY CONTROL
VCO TUNING VOLTAGE MONITOR
LOCK DETECT SIGNALS

12780 to 13280 MHz
SMA FEMALE
+8 dBm

Figure 5-7. Up Converter Synthesizer Diagram

5.5 Down

Converter

The function of the down converter is to convert the Ku-band signal from the LNA to a
70 MHz IF signal for use in the modem.

Refer to Figure 5-8 for a functional block diagram of the down converter.