beautypg.com

Chapter 6: maintenance, Test points and leds, Chapter 6. maintenance – Comtech EF Data KST-12025 User Manual

Page 107

background image

Rev. 1

6–1

6

Chapter 6.

MAINTENANCE

This chapter provides information on how to use the test points and LEDs on the M&C
board for troubleshooting. In addition, this chapter provides guidelines for
troubleshooting faults.

6.1

Test Points and LEDs

Test points and LEDs are included on the M&C board for quick troubleshooting
references. LEDs are a visual reference. Test points are used when more troubleshooting
is required.

Refer to Table 6-1 for a list of LEDs and their functions. Refer to Table 6-2 for a list of
test points on the M&C board.

Table 6-1. M&C LEDs

Name

Color

Description

HPA FLT

Red

Illuminates when the high-power amplifier is faulted. This fault will
cause the transmitter to turn off.

LD IF

Red

Illuminates when the IF local oscillator is out of lock. This fault will
cause the transmitter to turn off.

LD UC

Red

Illuminates when the up converter local oscillator is out of lock. This
fault will cause the transmitter to turn off.

LD DC

Red

Illuminates when the down converter local oscillator is out of lock.
This fault will cause the transmitter to turn off.

LNA FLT

Red

Illuminates when the LNA is faulted.

RF ON

Yellow

Illuminates when the high-power amplifier is turned on.

12.5V

Green

Illuminates when 12.5V is applied to board.

5V

Green

Illuminates when 5V is applied to board.