Comtech EF Data KST-12025 User Manual
Page 115
![background image](https://www.manualsdir.com/files/778817/content/doc115.png)
KST-12025 Ku-Band Satellite Terminal
Remote Control Operation
Rev. 1
A–5
Select Preset
Config
Command:
Response:
Status:
Response:
1
UCF_nnnnn.n'cr'
DCF_nnnnn.n'cr'
UCA_nn.n'cr'
DCA_nn.n'cr'
2
UCF_nnnnn.n'cr'
DCF_nnnnn.n'cr'
UCA_nn.n'cr'
DCA_nn.n'cr'
3
UCF_nnnnn.n'cr'
DCF_nnnnn.n'cr'
UCA_nn.n'cr'
DCA_nn.n'cr''lf']
Where: n = 1, 2, or 3.
Allows the user to select any one of three 'PreSet' configurations. The
user must first program (store) a configuration using the 'PGM_n'
command defined below. This command used without the 'PreSet'
number (n) will provide the current programming of each of the three
'PreSets'.
nnnnn.n = 14000.0 to 14500.0 MHz
nnnnn.n = 10950.0 to 12750.0 MHz
nn.n = 0 to 25.0 dB (UC Fine Adj)
nn.n = 0 to 20.0 dB (DC Fine Adj)
nnnnn.n = 14000.0 to 14500.0 MHz
nnnnn.n = 10950.0 to 12750.0 MHz
nn.n = 0 to 25.0 dB (UC Fine Adj)
nn.n = 0 to 20.0 dB (DC Fine Adj)
nnnnn.n = 14000.0 to 14500.0 MHz
nnnnn.n = 10950.0 to 12750.0 MHz
nn.n = 0 to 25.0 dB (UC Fine Adj)
nn.n = 0 to 20.0 dB (DC Fine Adj)
Program
Preset Config
Command:
Response:
Status:
Response:
1
xxxxxxxxxx'cr'
2
xxxxxxxxxx'cr'
3
xxxxxxxxxx'cr''lf']
Where: n = 1, 2, or 3.
Allows the user to store (program) the current frequency and
attenuator setting as one of three 'PreSet' selections.
(xxxxxxxxxx = 'Programmed' or 'None'.)
Clear
Program
Preset Config
Command:
Response:
Status:
Response:
1
xxxxxxxxxx'cr'
2
xxxxxxxxxx'cr'
3
xxxxxxxxxx'cr''lf']
Where: n = 1, 2, or 3.
Allows the user to clear (unprogram) the current frequency and
attenuator setting for one of three 'PreSet' selections.
(xxxxxxxxxx = 'Programmed' or 'None'.)
Lock Mode
Command:
Response:
Status:
Response:
Where: xx = LK (lock) or EN (enable, the default).
Lock mode prevents the current settings from being changed.