Errata b, Efdata documentation update – Comtech EF Data KST-12025 User Manual

Page 5

background image

Filename: T_ERRATA

1

Errata B

EFData Documentation Update

Subject:

Changes to power input requirements.

Date:

April 9, 1997

Document:

KST-12025 Ku-Band Satellite Terminal System Installation and
Operation Manual, Rev. 1, dated August 19, 1996

Part Number:

MN/KST12025.EB1

Collating Instructions:

Attach this page to pages 1-1 and 2-21

Comments:

The following changes provide the correct information for AC power input requirements. This
information will be incorporated into the next revision.

Change Specifics:

As incorrectly specified Chapter 1, page 1-1:

Prime Power Options

90 to 230 VAC, 47 to 63 Hz, using a 6’ cable North
American 3-prong plug, or 48 VDC (40 to 50 V)

This information should be changed to:

Prime Power Options

190 to 240 VAC, 47 to 63 Hz, using a 6’ cable North
American 3-prong plug, or 48 VDC (40 to 50 V)

As incorrectly specified Chapter 2, page 2-21:

The AC power is supplied to the RFT by a 3-pin power connector. Normal input voltage is 90 to 232 VAC,
47 to 63 Hz.

This information should be changed to:

The AC power is supplied to the RFT by a 3-pin power connector. Normal input voltage is 190 to 240 VAC,
47 to 63 Hz.