Remote Control Operation
CST-5005 C-Band Satellite Terminal
A–6
Rev. 1
External
Fault
Enable
Command:
Response:
Status:
Response:
Where: xxx = ON (the default) or OFF.
LNA Power
Enable
Command:
Response:
Status:
Response:
Where: xxx = ON (the default, enable power) or OFF.
Select
Preset
Config
Command:
Response:
Status:
Response:
Where: n = 1, 2, or 3.
1
UCF_nnnn.nnn'cr'
nnnn.nnn = 5845.0 to 6425.0 MHz.
DCF_nnnn.nnn
nnnn.nnn = 3620.0 to 4200.0 MHz.
UCA_nn.n'cr'
nn.n = 0.0 to 25.0 dB (UC Fine Adj).
DCA_nn.n'cr'
nn.n = 0.0 to 21.0 dB (DC Fine Adj).
2
UCF_nnnn.nnn'cr'
nnnn.nnn = 5845.0 to 6425.0 MHz.
DCF_nnnn.nnn
nnnn.nnn = 3620.0 to 4200.0 MHz.
UCA_nn'cr'
nn.n = 0.0 to 25.0 dB (UC Fine Adj).
DCA_nn n'cr'
nn.n = 0.0 to 21.0 dB (DC Fine Adj).
3
UCF_nnnn.nnn'cr'
nnnn.nnn = 5845.0 to 6425.0 MHz.
DCF_nnnn.nnn
nnnn.nnn = 3620.0 to 4200.0 MHz.
UCA_nn.n'cr'
nn.n = 0.0 to 25.0 dB (UC Fine Adj).
DCA_nn.n'cr''lf']
nn.n = 0.0 to 21.0 dB (DC Fine Adj).
Allows the user to select any one of three 'PreSet'
configurations. The users must first program (store) a
configuration using the PGM_n command defined below. This
command used without the Preset number (n) will provide the
current programming of each of the three Presets.
Redundant
Switch
Mode
Command:
Response:
Status:
Response:
Where: xxxxx = INDEP (the default) or DEP.
Note: For use in redundant system only with RSU-503 switch.
(INDEP TX and RX switch independently on fault to backup
terminal. DEP switches both TX and RX on fault to backup
terminal.)
Program
Preset
Config
Command:
Response:
Status:
Response:
Where: n = 1, 2, or 3.
1
xxxxxxxxxx'cr'
xxxxxxxxxx = 'Programmed' or 'None'.
2
xxxxxxxxxx'cr'
3
xxxxxxxxxx'cr''lf']
Allows the user to store (program) the current frequency and
attentuator settings as one of three 'PreSet' selections.