3 terminal default conditions, 4 theory of operation, 1 remote interface specification – Comtech EF Data CST-5005 User Manual

Page 74

background image

Theory of Operation

CST-5005 C-Band Satellite Terminal

5–4

Rev. 1

5.1.2.1 Remote Interface Specification

Refer to Appendix A.

5.1.3 Terminal Default Conditions

On initial power-up, the unit will default to the following parameters:

Parameter

Default

Baud Rate

9600

Parity

Even

Device Address

1

U/C Gain

Max gain/or min attenuation

D/C Gain

Max gain/or min attenuation

RF Output

OFF

U/C Frequency

6135.00 MHz

D/C Frequency

3925.00 MHz

5.1.4 Theory of Operation

Refer to Figure 5-3 for a functional block diagram of the M&C.

The M&C board performs the following operations:

Receives the desired frequency from either the remote RS-232-C/485 or KP-10
keypad, and after converting it to a synthesizer setting, stores it to the applicable
synthesizer output latch.

Reads the thermistors located in the up converter, down converter, and high-
power amplifier, and converts them to temperatures for display.

Reads the characterization EEPROMs in the up converter, down converter, and
high-power amplifier, and calculates an Automatic Gain Control (AGC) voltage
based on frequency and temperature to linearize the respective module.

Receives fault inputs from all modules, and presents them to the remote
RS-232-C/485 and the optional KP-10 keypad display.

Performs an initial current sense on the LNA, and stores the reading in
EEPROM. Subsequent current sense readings are taken and compared to the
initial reading to determine a fault.