Remote Control Operation

CST-5005 C-Band Satellite Terminal

A–8

Rev. 1

A.4 Status Commands/Responses

Config Status

Command:
Response:

>add/OS_'cr'
UCF_nnnn.nnn'cr'
DCF_nnnn.nnn'cr'
RF_xxx'cr'
DCA_nn.n'cr'
UCA_nn.n'cr'
SEL_n'cr''lf']

nnnn.nnn = 5845.0 to 6425.0 MHz.
nnnn.nnn = 3620.0 to 4200.0 MHz.
xxx = ON, WRM, or OFF.
nn.n = 0.0 to 21.0 dB. DC Fine Adj.
nn.n = 0.0 to 25.0 dB. UC Fine Adj.
n = 1, 2, 3, or None.

The command returns a block of data to be returned by the
addressed RFT-505.

The block of data reflects the current configuration status.

Fault Status

Command:
Response:

>add/FS_'cr'
RST_xxx'cr'
UL_xxx'cr'
DL_xxx'cr'
PS5_xxx'cr'
P12_xxx'cr'
HPA_xxx'cr'
LNA_xxx'cr'
SYN_xxx'cr'
ILD_xxx'cr'
OSC_xxx'cr'
UCM_xxx'cr'
DCM_xxx'cr'
SL2_xxx'cr''If']

See Note

xxx = OK or FLT.

Unit experienced a restart.

xxx = OK or FLT.

Uplink fault.

xxx = OK or FLT.

Downlink fault.

xxx = OK or FLT.

+5V power supply.

xxx = OK or FLT.

+12V power supply.

xxx = OK or FLT.

Power amp fault.

xxx = OK or FLT.

LNA fault.

xxx = OK or FLT.

Synthesizer1 L0 Lock Detect.

xxx = OK or FLT.

IF LO Lock Detect.

xxx = OK or FLT.

10 MHz REF OSC.

xxx = OK or FLT.

UC Module fault.

xxx = OK or FLT.

UC Module fault.

xxx = OK, FLT, or NA.

Synthesizer2 L0 Lock Detect.

This command returns a block of data reflecting the current
and logged faults. Logged faults will be reset when receiving
this command, while current faults can be read on the second
request.

Note: Valid only in dual synthesizer systems, else N/A.

Summary
Fault Status

Command:
Response:

>add/SF_xxx'cr''lf']

Where: xx = OK or FLT.

Returns status of current faults only.

Maintenance
Status

Command:
Response:

>add/MS_'cr'
UCT_nn'cr'
DCT_nn'cr'
HPT_nn'cr'

nn = UC temperature in degrees C.
nn = DC temperature in degrees C.
nn = Power Amp temp in degrees C.

This command returns a block of data from the RFT-505
reflecting the status of certain internal parameters for the
purpose of troubleshooting.

Equipment
Type Status

Command:
Response:

>add/ET_xx'cr''lf']

Where: xx = RFT-505 SW_1.00.

This command returns the equipment type polled and
software version.