A.4 status commands/responses – Comtech EF Data CST-5005 User Manual
Page 100

Remote Control Operation
CST-5005 C-Band Satellite Terminal
A–8
Rev. 1
A.4 Status Commands/Responses
Config Status
Command:
Response:
UCF_nnnn.nnn'cr'
DCF_nnnn.nnn'cr'
RF_xxx'cr'
DCA_nn.n'cr'
UCA_nn.n'cr'
SEL_n'cr''lf']
nnnn.nnn = 5845.0 to 6425.0 MHz.
nnnn.nnn = 3620.0 to 4200.0 MHz.
xxx = ON, WRM, or OFF.
nn.n = 0.0 to 21.0 dB. DC Fine Adj.
nn.n = 0.0 to 25.0 dB. UC Fine Adj.
n = 1, 2, 3, or None.
The command returns a block of data to be returned by the
addressed RFT-505.
The block of data reflects the current configuration status.
Fault Status
Command:
Response:
RST_xxx'cr'
UL_xxx'cr'
DL_xxx'cr'
PS5_xxx'cr'
P12_xxx'cr'
HPA_xxx'cr'
LNA_xxx'cr'
SYN_xxx'cr'
ILD_xxx'cr'
OSC_xxx'cr'
UCM_xxx'cr'
DCM_xxx'cr'
SL2_xxx'cr''If']
See Note
xxx = OK or FLT.
Unit experienced a restart.
xxx = OK or FLT.
Uplink fault.
xxx = OK or FLT.
Downlink fault.
xxx = OK or FLT.
+5V power supply.
xxx = OK or FLT.
+12V power supply.
xxx = OK or FLT.
Power amp fault.
xxx = OK or FLT.
LNA fault.
xxx = OK or FLT.
Synthesizer1 L0 Lock Detect.
xxx = OK or FLT.
IF LO Lock Detect.
xxx = OK or FLT.
10 MHz REF OSC.
xxx = OK or FLT.
UC Module fault.
xxx = OK or FLT.
UC Module fault.
xxx = OK, FLT, or NA.
Synthesizer2 L0 Lock Detect.
This command returns a block of data reflecting the current
and logged faults. Logged faults will be reset when receiving
this command, while current faults can be read on the second
request.
Note: Valid only in dual synthesizer systems, else N/A.
Summary
Fault Status
Command:
Response:
Where: xx = OK or FLT.
Returns status of current faults only.
Maintenance
Status
Command:
Response:
UCT_nn'cr'
DCT_nn'cr'
HPT_nn'cr'
nn = UC temperature in degrees C.
nn = DC temperature in degrees C.
nn = Power Amp temp in degrees C.
This command returns a block of data from the RFT-505
reflecting the status of certain internal parameters for the
purpose of troubleshooting.
Equipment
Type Status
Command:
Response:
Where: xx = RFT-505 SW_1.00.
This command returns the equipment type polled and
software version.