3 spar installation – Comtech EF Data CST-5005 User Manual

Page 64

background image

Redundant System Installation

CST-5005 C-Band Satellite Terminal

3–16

Rev. 1

3.3.2.2 Square Pole

For square vertical pole installation, follow the steps in Section 3.3.2.1, with the
following exceptions:

Do not perform Step 4.

Do not perform Step 6.e.

3.3.3 Spar Installation

Note: The following process is for a typical installation. Custom kits may be ordered and
are beyond the scope of this manual.

To install the RFTs to a spar:

1. Set the units on their side, with the mounting holes facing up.

2. Install the 8” unistruts as follows:

a.

Position an 8” unistrut (with the open
side facing up) over one set of the
mounting holes on an RFT.

b. Using four 1/4-20 bolts, 1/4” split

lockwashers, and 1/4” flat washers,
attach an 8” unistrut to the RFT.

Tighten the bolts firmly.

c. Repeat Steps 2.a. and 2.b. for the

remaining 8” unistruts (for a total of
four).