CST-5005 C-Band Satellite Terminal

Remote Control Operation

Rev. 1

A–7

Clear
Program
Preset
Config

Command:
Response:

Status:
Response:

>add/CPGM_n'cr''lf']

>add/CPGM_'cr'

Where: n = 1, 2, or 3.

1

xxxxxxxxxx'cr'

xxxxxxxxxx = 'Programmed' or 'None'.

2

xxxxxxxxxx'cr'

3

xxxxxxxxxx'cr''lf']

Allows the user to clear (unprogram) the frequency and
attentuator setting for one of three 'PreSet' selections.

RS-232
Address
Select

Command:
Response:

Status:
Response:

>add/AS_xxx'cr''lf']

>add/AS_xxx'cr''lf']

Where:

add = current address.
xxx = new address, 1 to 255. Default address = 1.

RS-232
Baud Rate
Select

Command:
Response:

Status:
Response:

>add/BR_xxxxx'cr''lf']

>add/BR_xxxxx'cr''lf']

Where: xxxxx = 300 to 19200, in standard settings of 300, 600,
1200, 2400, 4800, 9600, and 19200. Default = 9600.

RS-232
Parity
Select

Command:
Response:

Status:
Response:

>add/PS_xx'cr''lf']

>add/PS_xx'cr''lf']

Where: xx = OD (odd), EV (even, the default), or
NO (none - 8 bit).