XR2500F Installation Guide
30
InstallatIon
28.5 Proprietary Dialer
The Model XR2500F provides proprietary service when configured as a digital dialer.
28.6 DACT Central Station
DACT Central Station service can be provided under by adding an Ademco AB12M bell and bell housing.
28.7 Bell Cutoff
The Bell Cutoff time cannot be less than 15 minutes.
28.8 Standard or Encrypted Line Security
Standard Line Security is provided when configured as a Path 1 NET system using an XR500N panel. The NET
Check-in time must be set to 06 minutes or RDM. When programmed for Standard Line Security, Exit Time
Restart is disabled. When a dialer is required for 06 minute check-in time, an attack resistant enclosure
(DMP Model 350A) is required. When the check-in time is set to a number less than 200 seconds, an attack
resistant enclosure is not required.
To provide Encrypted Line security, install an XR500E panel.
For Encrypted Line security operation, communication between the Premise and Supervising Station provides
128 bit encryption when using an XR500E panel or an XR500 panel with an iCOM-E Encrypted Network Alarm
Router.
The Model XR500 Series Protected Premises Control Unit is suitable for Standard Line Security service when
configured for NET communication with SCS-1R receiving system. This configuration is approved for the
following:
AMCX - Central Station Alarm Units
APOU - Proprietary Alarm Units
28.9 Wireless Audible Annunciation Option
The Wireless Audible option must be selected as ANY for commercial applications.
28.10 Model 463G CELL Only, Standard or Encrypted Line Security
Standard or Encrypted Line Security is provided when programmed using CELL with no backup. XR500
cellular communication is used as primary with a 3 minute check-in when armed or disarmed.
Path 1 programming
Comm Type: = CELL
Checkin: = 3 minute
Path Type: = Primary
Fail Time: = 3 minute
Encrypt: = NO or YES*
Test Rpt: = NO
Sub Code: = NO or YES
*For Encrypted Line Security, program a Passphrase in Network Options.