InstallatIon
J1 Ethernet Connector
22.1 Description
The J1 Ethernet Connector is available to connect directly to an Ethernet network using a standard patch
cable. The maximum line impedance is 100 Ohms.
J1
Ethernet
Link LED
Activity LED
Figure 15: J1 Header and LEDs
22.2 Ethernet LEDs
The two LEDs, located to the left of J1 Ethernet Connector, indicate network operation. The top, Activity
LED flashes green to indicate the network traffic is good. The bottom, Link LED flashes yellow to indicate
messages are being sent and received.
Reset and Tamper Headers
23.1 J16 Reset Header
The reset header is located just above the terminal strip on the right side of the circuit board and is used
to reset the XR2500F microprocessor. To reset the panel when first installing the system, install the reset
jumper	before	applying	power	to	the	panel.	After	connecting	the	AC	and	battery,	remove	the	reset	jumper.	
To	reset	the	panel	while	the	system	is	operational,	for	example,	prior	to	reprogramming,	install	the	reset	
jumper	without	powering	down	the	system.	Remove	the	reset	jumper	after	one	or	two	seconds.
After	resetting	the	panel,	begin	programming	within	30	minutes.	If	you	wait	longer	than	30	minutes,	you	
must reset the panel again.
J6
Interface
Card
Expansion 
Connector
Momentarily place the Reset 
jumper over both of the J16 
pins to reset the panel.
AC
1
2
3
4
5
6
7
8
10
11
12 13
14
15 16
17 18
19
9
20
21 22
23
24
25
26
27
28
+B
BELL GND
SMK GND
RED YEL GRN BLK
Z1
Z2
Z3
Z4
Z5
Z6
Z7
Z8 Z9+ Z9– Z10+ Z10–
AC
–B
GND
GND
GND
GND
K6
K7
Output 1
Output 2
J3
Phone Line
J10
J22
LX-Bus
Battery 
Start
J23
J21
RS-232
Power 
LED
J8
PROG
J4
Tamper
J16
Reset
Out
1
O
ut
2
Outputs 3-6
J11
3 
4 
5 
6
J2
J1
Ethernet
R
L
X
OVC
Link LED
Activity LED
Figure 16: XR2500F Panel Showing the Reset Jumper
23.2 J4 Tamper Header
The J4 header is for use with the optional DMP 306 Tamper Harness. The harness connects to one or more
tamper switches mounted inside the panel enclosure to supervise against unauthorized enclosure opening or
removal.	Refer	to	the	wiring	diagram	on	the	enclosure	door	for	correct	tamper	switch	wiring.
How the Tamper Works
If	the	enclosure	is	opened	or	removed	while	one	or	more	of	the	system	areas	are	armed,	a	panel	tamper	